Nominal Data
|
|
At room temperature (ambient
temperature of 20°C) |
|
Power Ratings
|
|
Operated at room temperature
under Nominal Load conditions. |
|
Temperature Rise
|
|
The temperature rise was
calculated by the resistance formula used by UL as well as VDE. |
|
Operating Temperatures
|
|
-40C up to 80C, unless otherwise
specified. |
|
Storage Temperatures
|
|
-30C up to 120°C. |
|
Dimensions
|
|
All dimensions are in mm. |
Temperature Rise/Secondary Voltage

Secondary Load

HiPot Testing and Surge
Testing
HiPot Tests are performed
between windings of opposite polarities. We perform a 5,000 V RMS HiPot
Test on our complete line of transformers. We can offer transformers
that are HiPot tested up to 15,000 V RMS.
The Impulse Surge Test is a high voltage
wave of up to 12,000 V RMS with a specified rise time and a specified
duration that is applied to the primary winding of the transformer (see
IEEE C62.41). It simulates surges caused by lightning or power-factor
correction. We specialize in miniature transformers that meet these
requirements.
|